Electrolyte formulation and testing
We mix electrolytes to the composition you specify, then measure what they do. Lithium and sodium systems in research quantities, including blends that no supplier keeps in stock.
Services
Most suppliers sell from a fixed catalogue and ship a certificate of analysis. We work from your specification instead, and the measurements come with the bottle.
You give us the salt, the solvent ratio and the additives. We prepare it under argon and send it with a sheet listing exactly what went in.
Ionic conductivity across a temperature range, impedance spectroscopy, and coin cell cycling. You get the data files, not only a summary table.
Salts and solvents are tested for water and free acid before we use them. Every lot has a recorded result, and we will show it to you.
Handling
Electrolyte testing usually runs on repeated pipetting, open vials and manual transfers. Even inside an argon glovebox, solvent evaporates off an open tip, trace moisture finds its way in, and pipetted volumes drift between batches. Those shifts change the interphase that forms, which changes cycle life, which changes the conclusion you draw.
The liquid is not exposed to the glovebox atmosphere or to shared tools between leaving its container and reaching the cell.
Volumes are delivered at a set amount rather than pipetted by hand, so the dose does not drift from one cell to the next across a batch.
Each formulation gets its own single-use fluid path, so nothing carries over from the composition before it.
The ppm figure on the certificate is meant to be the figure when the cell is sealed, not the figure when the bottle was filled.
This matters most where the chemistry is delicate: SEI-forming additives, high-voltage cathodes, sodium systems. Your cycling data should describe the electrolyte you chose, not the handling it went through on the way in.
In the lab
Mixing and handling are done under argon. Water is kept low enough that the salts do not start breaking down before the experiment does.
EIS across frequency and temperature. Cell constants are measured against a KCl standard rather than taken from the manufacturer's sheet.
Conductivity measured over a temperature range, with the Arrhenius fit reported where the data supports one.
We build and cycle 2032 coin cells so that two electrolytes can be compared on the same electrodes and the same schedule.
LiPF6, LiFSI and LiTFSI, the sodium equivalents, and ionic liquid based systems as well as carbonates.
Each batch leaves with its composition, its water content and whatever properties we measured, on paper.
Background
It decides how fast a cell can charge, how cold it can run, and what layer forms on the electrodes during the first cycles. Most groups buy it from a catalogue and then work around whatever they were sent.
Figures above are from published work on lithium-ion cell manufacturing. They are not Formulyte measurements.
How we work
We are a small lab. That sets what we can take on, and it is also why the record keeping is tight.
Nothing ships on the assumption that it came out right. You get the measurement and the file it came from.
Orders start at the scale an experiment actually needs. There is no 500 gram minimum.
If a measurement does not reproduce, it goes in the report that way instead of being quietly dropped.
Contact
Tell us the chemistry, how much you need, and what you want measured. We will come back with a price and a date.
We work with university research groups, battery startups and industrial R&D teams, on custom formulations and on the handling protocol around them.
contact@formulyte.com